Sign In | Join Free | My tjskl.org.cn
China Kingsine Electric Automation Co., Ltd. logo
Kingsine Electric Automation Co., Ltd.
Kingsine Electric Automation Co., Ltd. Specialize in Electric Power Testing
Verified Supplier

16 Years

Home > Protection Relay Testing >

K3166i Protective Relay Tester / Protection Relay Test Equipment

Kingsine Electric Automation Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment

K3166i Protective Relay Tester / Protection Relay Test Equipment

Brand Name : KINGSINE

Model Number : K3166i

Certification : ISO9001,CE

Place of Origin : China

MOQ : 1 set

Payment Terms : T/T in advanced, L/C

Supply Ability : 50 sets/month

Delivery Time : 15 working days

Contact Now

K3166i Universal Relay Test Set

(All-in-one design,complying IEC61850 SV & GOOSE)

Output Current: 6×35A@450VA max.

3×70A@850VA max.

Output Voltage: 7×310V@90VA max.

Features

All-in-One design, Integrated IEC61850 SV & GOOSE, 6I+7V analog channels output, Inbuilt GPS and IRIG-B, and other advance functions.

1. Complied IEC61850-9-1, IEC61850-9-2, IEC60044-7/8, etc.

2. 100/1000Mbit Fiber ports for SMV and GOOSE simulations.

3. 6×35A & 7×310V independent high burden output channels.

4. 13 channels independent low-level signal outputs.

5. AC/DC measurement (8 channels inputs,class 0.1,0-600V/0-5A,auto range).

6. Transducer calibartion (class 0.02).

7. Energy meter calibration ( Mechanical & Electronic meters ).

8. Analog and Binary Transient Record.

9. Transient play back up to 3KHZ.

10. Light weight <18kg

11. Fully function KRT software testing modules.

12. 3-Years guarantee of free repair and life-long maintenance.

13. Free software upgrade.

Ordering Ref.

Model Current Outputs Voltage Outputs
K3166i 6×35A@450VA max / 3×70A@850VA max 7×310V@90VA max
K3163i 6×35A@450VA max / 3×70A@850VA max 4×310V@124VA max
K3130i 3×35A@450VA max 4×310V@124VA max
K3166 6×35A@450VA max / 3×70A@850VA max 7×130V@75VA max
K3163 6×35A@450VA max / 3×70A@850VA max 4×130V@75VA max
K3130 3×35A@450VA max 4×130V@75VA max

Application

Testing Items ANSI® No.

IEC61850 numerical IEDs relay & merge unit --

Distance protection relay 21

Synchronising or synchronism-check relays 25

Undervoltage relays 27

Directional Power relays 32

Undercurrent or underpower relays 37

Negative sequence overcurrent relays 46

Overcurrent/ground fault relays 50

Inverse time overcurrent/ground fault relays 51

Power factor relays 55

Overvoltage relays 59

Voltage or current balance relays 60

Directional overcurrent relays 67

Directional ground fault relays 67N

DC overcurrent relays 76

Phase-angle measuring or out-of-step protection relays 78

Automatic reclosing devices 79

Frequency relays 81

Motor overload protection relays 86

Differential protection relays 87

Directional voltage relays 91

Voltage and power directional relays 92

Tripping relays 94

Voltage regulating relays --

Overimpedance relays, Z> --

Underimpedance relays, Z --

Time-delay relays --

Characteristic

1. 13 Channels (6×35A & 7×310V) outputs, each output channels are independent and simultaneous.

2. Variable battery simulator, DC 0-350V, 140Watts max.

3. 13 Low-level channels outputs up to 8Vac/10Vdc max.

4. 0-600V / 0-5A AC/DC measurement in 0.1 class.

5. Graphical test modules and templates for testing of various relays.

6. Quick relay testing facility in Manual mode.

7. Shot/Search/Check, Point & Click testing.

8. RIO/XRIO import & export facility.

9. Switch on to fault test(SOTF).

10. Power system model for dynamic testing.

11. Inbuilt GPS and IRIG-B sync end-to-end testing.

12. Online Vector display.

13. Automatic test results assume.

14. Automatic test report creation.

15. Anti-clipping detect,wrong wiring connect alarm and self-protect, overload and overheat protection.

Parameter

Voltage Outputs
Output Range & Power 7×310V ac (L-N) 90VA max each
3×620V ac (L-L) 180VA max each
3×350V dc (L-N) 140W max each
Accuracy AC:<0.03%Rd + 0.01Rg Typ. / <0.07%Rd + 0.03Rg Guar.
DC: ±10mV @<5V,±0.5% @ ≥5V
Resolution 1mV
Distortion <0.05% Typ. / <0.1% Guar.
Current Outputs
Output Range & Power 6×35A ac(L-N) 450VA max each
3×70A ac(2L-N) 850VA max each
1×100A ac(6L-N) 1200VA max
3×20A dc(L-N) 300W max each
Accuracy AC:<0.05%Rd + 0.02Rg Typ. / <0.15%Rd + 0.05Rg Guar.
DC: ±5mA @<1A,±0.5% @ ≥1A
Resolution 1mA
Distortion <0.05%Typ. / <0.1% Guar.
13 Low-Level Channel Outputs
Quantity 13 Channels, 16 pin aviation socket
Voltage outputs range AC 0-8V, DC 0-10V
Current outputs range Nominal 2mA, 10mA max transient
Output Power ≥0.5VA
Accuracy (0.01~0.8 Vrms):<0.05% Typ. / <0.1% Guar.
(0.8~8 Vrms):<0.02% Typ. / <0.05% Guar.
Resolution 0.25mV
Distortion(THD%) <0.05%Typ. / <0.1% Guar.
Frequency & Phase Angle
Frequency Range DC~1KHZ, 3KHZ transient
Frequency Accuracy ±1ppm
Frequency Resolution 0.001Hz
Phase Range -360°~360°
Phase Accuracy <0.05°Typ. / <0.1° Guar. 50/60Hz
Phase Resolution 0.001°
IEC61850 Fiber & GOOSE Ethernet Ports (Optional Function)
Fiber Ports

2×100Base-FX Full Duplex,LC type


(Optional to 10/100Mbit, Ethernet RJ45 type)

Fiber Type 62.5/125um (Multiple optical fiber, Orange Red)
Wavelength 1310nm
Transmit Distance >1Km
Indicator

Spd Green(light):Valid connection


Link/Act Yellow(Blinking): Data exchanging

Note: All hardware of this module are ready for active.
Aux. DC Voltage Source(Battery simulator)
Range 0~350V @ 140W max
Accuracy 0.5%Rg Guar.
Binary Input
Quantity 8 pairs
Type wet/dry, measurement
Threshold 10~600Vdc or potential free, Programmable
Time resolution 100us
Debounce time 0~25ms(Software Controlled)
Time range Infinite
Time errors ±1ms @ 0.001~1s, ±0.1% @>1s
Galvanic isolation 4 isolated with each 2 pairs
Binary Output(Relay Type)
Quantity 4pairs
Type Potential free relay contacts,software controlled
Break Capacity AC Vmax: 400Vac / Imax:8A / Pmax:2500VA
Break Capacity DC Vmax: 300Vdc / Imax:5A / Pmax:150W
Binary Output (Semiconductor Type)
Quantity 4pairs
Type Open-collector, 14 pin Aviation socket
Break Capacity DC

5~15Vdc / 5mA, 10mA max


AC not permit

Response time 100us
Synchronization
Synchronization Mode  GPS, SMA type antenna connector / IRIG-B / FT3 IEEE1588
Power supply & Environment
Nominal Input Voltage 100~240Vac
Permissible Input Voltage 85~264Vac, 125~350VDC
Nominal Frequency 50/60Hz
Permissible Frequency 45Hz~65Hz
Power Consumption 1500 VA max
Connection Type Standard AC socket 60320
Operating Temperature -10℃~55℃
Storage Temperature -20℃~70℃
Humidity <95%RH, non-condensing
Others
PC Connection RJ45 Ethernet, 10/100/1000M
Grounding Terminal 4mm banana socket
Weight 18Kg
Dimensions(W×D×H) 468×375×164(mm)

Optional Modules

DC Measurement Input (Transducer calibrator)

◆ Voltage input

Range: 0~±10V dc

Max Input: ±11V dc

Accuracy: <0.02% rg Typ. / <0.05% rg Guar.

Input Impedance: 1M ohm

◆ Current Input

Range: 0~±1mA / 1~20mA, auto range

Max Input: 600mA

Accuracy: <0.02% rg Typ. / <0.05% rg Guar.

Input Impedance: 15 ohm

AC / DC Measurement Input( Standard meter )

◆ Input Quantity: 8 channels (blend with binary input pairs).

◆ Voltage rang: 0~600Vrms (Rg: 0.1V,1V,10V,60V,600V).

◆ Voltage accuracy: <0.1% Rg

◆ Current range: 0~5Arms (Clamp input, 30Arms optional).

◆ Current accuracy: <0.1% Rg.

◆ Sample rate: 10KHz.

◆ Input impedance: 600KΩ

◆ Frequency range: 45~65Hz, Accuracy<0.01Hz.

◆ Phase accuracy: 0~360°,<0.2° Typ.

Transient Recorder

◆ Input Quantity: 8 input channels (blend with binary input pairs).

◆ Recorder time: Max 50 Sec.

Energy Meter Calibration

◆ Sensor Usage: Mechanical meters / Electronic meters.

◆ Sensor Output: High level : >4.5V, Low level: <0.2V.

◆ Pulse Input: 1 pulse input port.

◆ Pulse Range: 500KHz pulse input Max.

◆ Pulse Output: 1 Transistor output, Open-collector, 5-15Vdc/5mA.


Product Tags:

protective relay tester

      

relay protection tester

      
Quality K3166i Protective Relay Tester / Protection Relay Test Equipment for sale

K3166i Protective Relay Tester / Protection Relay Test Equipment Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Kingsine Electric Automation Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)